NL95
Touch Screen Navigational Light Controller
New!
logo_brand_aquasignal
GL_DNV 115V-230V_AC 24V_DC
NL95_00_main_unit_front_view_splash_screen

NL95 main unit, front view

NL95

NL95 is a programmable control and monitoring system for navigation and signal lights. Built-in software allows easy programming of lights configuration in main unit itself without requirement of external devices. A modular and scalable design makes it suitable for all ships / vessels types and sizes, with remote control feature it is possible to integrate it with ship control system.

The complete unit contains of a main display with touch panel for flush mounting, input modules for lanterns connection and power supply unit for installation inside of bridge console or in technical room. The NL95 main unit is equipped with touch screen display, and runs a user-friendly and easy-to-use operating system. It is available in 230 V AC, 115 V AC, or 24 V DC versions depending on vessel main power supply. 

All versions have dual power supply input modules (main and spare) with automatic change-over function. NL95 continuously monitors status of lights that are switched on and light's circuitry by checking current consumption for each individual connected navigational light or signal light. If current drops below threshold, the alarm is activated and system automatically switches to spare light (if exists), however this provides more safety. Each light input is protected by double pole fuse. Input modules are equipped with manual override activation feature which allows operation even in case of electronic failure. 

NL95, in maximum configuration, controls up to 80 lights, i.e 30 double lights and 20 single or up to 50 single lights. NL95 is tested and compatible with standard bulbs and Glamox / aqua signal LED navigation lights Series 60, 61, 65, 75, 66N(D) MIL,75 and 76N(D). 

In addition, NL95 is Bureau Veritas, CRS, and DNV-GL certified.

Navigation Light Configurator 

Glamox offers a Navigation Light Configuratur that will make it easy for you to find the correct products and solutions for your project. Test it out!

Electric

230 V AC or 115 V AC or 24 V DC , depending on version connection, main and emergency power supply with automatic change-over, automatic supply change-over signalling.

Approvals

DNV-GL, BV and CRS

Maximal / Possible Configuration

Maximum number of lights: 
80 (in configuration 30 double lights and 20 single lights) 
Up to 5 input modules (in total) can be installed 
Up to 3 pcs. of ITNL-10-D (double lights) 
Up to 5 pcs. of ITNL-10-S (single lights) 
ITNL-10-D and ITNL-10-S can be combined in the same system

Lights' Power Range

4-100 W (230 V AC) 
4-65 W (115 V AC) 
4-40 W (24 V DC) 
Flashing lights are allowed

Input Modules Power Range

800 W (230 V AC) 
430 W (24 V DC)

Lights' Fuses

5x20mm, each pole, mounted on input modules

Lights' turn on/off in case of emergency

Manual activation of lights directly on input modules, power supply

Alarm/Signalisation output

SYSTEM OPERATING voltage-free C.O. contacts 250 V ac/1A, for indicating that system is functioning correctly, COMMON ALARM voltage-free C.O. contacts 250 V ac/1A, for broken light circuit alarm and power/system failure alarm NMEA 0183 TRANSMITTER - $NLALR sentences for normal state, alarm state, main and emergency supply alarms

Communications between modules

RS485, ITNL addresses configured via dip switch

Lights' configuration and condition

Presented on 7” TFT touch display

Lights' switch on/off mode

Using groups for switch on, touching light’s icon for toggle between on and off, and switch off all using “ALL OFF” button

Dimmer Button

Configurable, could be use to adjust display intensity in steps, or day / night intensity level switching
NL95_06_power_supply_module

NL95 Power Supply Module

NL95_06_input_modules

NL95 Input Modules

Product detail

NL95_06_power_supply_module NL95_06_input_modules
NL95_40_main_unit_outlines

Main Unit outlines

NL95_40_main_unit_panel_cut_out

Main Unit Panel cut-out

NL95_41_modules_codes

Modules Codes

NL95_41_power_supply_codes

Power Supply codes

Measurement drawings

NL95_40_main_unit_outlines NL95_40_main_unit_panel_cut_out NL95_41_modules_codes NL95_41_power_supply_codes
Find your version

Use this button to find the exact article number and more product details.


Documents

439KB
481KB
~3MB
~3MB

Marketing materials

849KB
Total size
Download